The DNR is an Intelligent non-relay photoelectric duct smoke detector for use with ONYX Series panels. The DNRW is a Watertight intelligent non-relay for use with ONYX Series panels. The FSL-751DNR is an Intelligent, high sensitivity duct smoke detector for use with ONYX Series panels. The Inn ovairFlex sampling tube may be installed f rom the f ont or back of the de tec. Life Safety Consultants is here to ensure your fire and smoke detectors are always in working order.
Wait two minutes for the duct smoke detector to alarm. If the duct smoke detector alarms, air is flowing through the detector. Remove the duct smoke detector cover and blow out the residual aerosol smoke from the chamber and reset the duct smoke detector. Use duct tape to seal the aero- sol smoke entry hole.
Smoke introduced into this air duct system will be distributed throughout the entire building. Smoke detectors designed for use in air duct systems are used to sense the presence of smoke in the duct. System Sensor is a global manufacturer of fire and life safety devices, in smoke detection , carbon monoxide detection , and notification technology. Duct detector housing complete with B501AP base for analogue detectors. Requires DSTXX duct sampling tube and sensor.
The FSD-751RP air duct smoke detector is a photoelectric detector. Detector not supplied). This smoke detection method combines with an efficient housing design that samples air passing through a duct and allows detection of a developing hazardous condi-tion. What is a conventional duct detector?
Where should duct smoke detectors be located? Do vavs require duct detector? Does not include hea watertight.
Morley-IAS addressable detectors ranging from standard smoke detection to multi-sensing specialty detection for intelligent fire alarm control panels. Duct sensor housing only, complete with base. Notifier recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors feet (44m) for ceiling heights feet (48m) and higher. For specific information regarding detector spacing, placement, and special applications refer to NFPA 72.
The detector housing shall be UL Listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits both square and rectangular footprints. I am simply supplying brand new, quality parts for your use. Once smoke is sense to prevent the air handlers from spreading the smoke throughout the building, the smoke dampers in the ductwork are closed and the air handling fans are shut down.
CDZ duct detector provided with B4base. RII70) o DST3(RII70A). Power from control panel.
If the tube is shorter than the width of the air duct , install the end plug into the inlet tube as shown in Figure and sup- port the end opposite the duct smoke detector. Install the inlet tube as follows: 1.