The Series Heat Detector monitors temperature by using a dual thermistor network which provides a voltage output proportional to the external air temperature. There are heat detectors in the Series range designed to suit a wide variety of operating conditions. When the temperature treshold is reache the alarm will be activated.
We produce analog addressable, conventional, duct mounte wireless and two-wire detectors coupled with system components and remote accessories, approved to local standards and regulations from across the globe. Detectors should not be cleaned in the field except for careful removal of exterior dirt with a damp cloth. The procedures are not a substitute for factory testing and recalibration. Refer to MAINTENANCE section for cleaning your alarm.
The XPHeat Detector monitors temperature by using a single thermistor which provides a count output proportional to the external air temperature. The XPrange features two heat detectors , standard and high temperature. The standard heat detector is classified as an A2S device and will report an alarm at 55°C. The way in which the signals from the two sensors are combined depends on the response mode selected. Manufacturers of high quality fire detection solutions - global suppliers based in the UK.
How does photoelectric smoke detector detect heat? What is a Honeywell heat detector? What are two type of heat detectors are? Monitors temperature using a dual thermistor network which provides a voltage output proportional.
Certified to EN54-by the LPCB. Wide 9-33V DC operating voltage. Red LED illuminates when the. Both smoke and heat elements can be tested simultaneously using this.
For Orbis Multisensor detectors place the control panel in ‘test’ mode OR remove the detector from the detector base then re-fit OR reset the control panel. The mounting bases contain an XPERT card which allows the detector to become part of the addressable fire alarm system. The packaging is such that the lid can be used as a dust cover until the commissioning of the system. These detectors are suitable for use on most modern conventional type fire alarm systems.
This LED illuminates when the detector has detected either smoke or heat to aid in the location of the detection source. By keeping track with the current market development, we are involved in offering optimum quality Intelligent Heat Detector. This detector is effective to warn people at the time of fire by detecting the smoke and fire. The offered detector is widely used in chemicals, automobile, factories and other industries.
A high specification programmable heat detector. User programmable to operate in one of five sensivity modes (e.g. Mode will give a higher senstivity to fire than Mode 5). Discovery heat detectors have a common profile with ionisation and optical smoke detectors but have a low air flow resistance case made of self-extinguishing white polycarbonate.
Each conventional apollo series fire alarm detector in The Safety Centre's range incorporates a LED. Fire Detection solution for the commercial and industrial market. To help you choose the right product, our technical team can answer your questions or alternatively complete the “call me back form” on the left side of our website and one of our specialists can advise you.