Conventional smoke detector

Conventional smoke detector

What do smoke detectors actually detect? What is the best home smoke detector? Where should you install your smoke detectors?


Conventional Smoke Detectors System Sensor is the world leader in commercial smoke detection. Our intelligent and conventional spot smoke detection lines provide the features and flexibility you need for your commercial fire or security system. The ifamily is founded on three principles: installation ease, intelligence, and instant inspection. Mircom carries a full line of smoke detection devices for our conventional fire alarm control panels. Select a device from the list below.


The 7Series conventional smoke detector is an interchangeable head and base detector with a light scattering optical sensor that provides an excellent response to a wide range of fires. The 7Series consists of two and four wire conventional photoelectric smoke , as well as photoelectric smoke with heat detectors. That means less wire, less labor, and less devices on the wall or ceiling.


Some of the features (depending on model number) include: - Built in drift compensation. Detector adjusts to the environment to reduce false alarms. CleanMe self diagnostics. NOTIFIER continuously develops new technologies that improve life safety in buildings worldwide.


Our solutions will help you determine the best system to meet the needs of your application. Conventional fire alarms are ideal for small buildings, such as individual offices or retail shops. They go off individually when they detect smoke or heat and will help everyone escape from your building safely and quickly. Addressable fire alarms are a necessity for large building complexes or campuses. Both types of alarm link devices (such as call points and smoke detectors ) to a main control panel.


The main difference between the two is that with addressable fire alarm systems, you can pinpoint exactly which device has been activated. Commercial smoke detectors are either conventional or addressable, and are connected to security alarm or fire alarm systems controlled by fire alarm control panels (FACP). These are the most common type of detector , and are usually significantly more expensive than single-station battery-operated residential smoke alarms. FIAKO is named as a famous trademark in fire alarm by FIAKO ELECTRONIC CO. We designed and produce high quality fire alarm products including fire alarm control panel, smoke detector, heat detector , manual call point, fire alarm bell, fire alarm sounder, soubder beacon, motor siren etc.


Conventional smoke detectors are for use with conventional fire alarm systems and are typically or 24V DC, depending on the panel. To facilitate location and control of a fire within a building, the structure is subdivided into definite areas or zones. The conventional detector range is designed to be used in environments where the ambient conditions might cause false alarms if smoke detection were to be use for example where there is a high level of dust, fumes or smoke under normal conditions. Conventional Beam Detectors Beam Detectors are used to provide “open area” smoke detection in situations where it is either impractical or not cost effective to use traditional point-type detectors or aspirating smoke detection. As a guide, space smoke detectors on smooth ceilings ft.


Conventional smoke detector

When determining other spacing, consider ceiling height, high air movement, and other conditions or response requirements. With TrueAlarm analog detection, data from the photoelectric chamber is monitored and analyzed at the detector to provide a continuously shifting reference point. The OSI-R(A)-SS is a Single-ended conventional beam smoke detector with integrated test feature for use with any panel. Reflected Beam Smoke Detectors are designed for spacious rooms, open areas, and high ceilings. Optical Smoke Detectors are ideal at detecting visually smoky fires which are likely to be slow, smouldering fires.


ABS casing with red LED fire indicator. Maximum of per zone. If the detector drifts out of its UL Listed sen-sitivity range or fails internal diagnostics, the alarm LED flashes once a second to indicate a trouble condition. A conventional Fire Alarm Control Panel employs one or more circuits, connected to smoke detectors and manual pull stations (initiating devices) wired in parallel. Floors of a multistory building are one type of zone boundary, for example.


A wide variety of conventional smoke detector options are available to you, such as smoke , fire, and personal. You can also choose from free samples, paid samples. There are 2conventional smoke detector suppliers, mainly located in Asia. The OSI-RI-SK is a intelligent addressable reflector-type linear optical beam smoke detector.


It is uniquely suited for protecting large open areas with high ceilings, where spot-type smoke detectors are difficult to install and maintain. Ideal applications include warehouses, atriums, aircraft hangers, sporting arenas and concert halls.